2. Display

2. Display
2
2.1. Display
Note:
Due to the advanced functionalities of the inverter, it may take up to 10 seconds before the
display becomes available after power up.
The integrated display on the inverter front gives the user access to all information about the
PV system and the inverter.
The display has two modes:
Normal
Power saving
Overview of display buttons and functionality:
Illustration 2.1: Display
Note:
The contrast level of the display can be altered by pressing the arrow up/down button while
holding down the F1 button.
The menu structure is divided into four main sections:
View
Status
Production Log
Setup
See the following sections for more detailed information.
4
The display is in use
After 10 min. of no display activity the back light of the display turns off to save power.
Re-activate the display by pressing any key
Presents a short list of information, read only.
Shows inverter parameter readings, read only.
Shows logged data.
Shows configurable parameters, read/write.
8000038784_00_BAL_en / L00410565-01_02
F1
View 1 / View 2 - Screen
F2
Status Menu
F3
Production Log Menu
F4
Setup Menu
* When an F-key is selected the LED above it will light
up.
Home
Return to View Screen
OK
Enter/select
Arrow up
A step up/increase value
Arrow Down
A step down/decrease value
Arrow Right
Moves cursor right
Arrow Left
Moves cursor left
Back
Return/de-select
On - Green LED
On/flashing = On grid/Connecting
Alarm - Red LED Flashing = Fail safe
The inverter is configured as mas-
ter. Icons can be found in the top
right corner.*
The inverter is connected to a mas-
ter. Icons can be found in the top
right corner.*
*) Protect PV easy only.