TROUBLESHOOTING GUIDE

GENERAL

Problem
Circuit breaker trips
or fuse blows when
unit is turned on
Unit turns on or off
by itself
Lights dim in room
while the unit is on
Power cord gets
warm

APPEARANCE

Problem
Fireplace does not
turn on
Flame frozen
Flame not bright or
flame not visible
Log set dim, ember
bed not glowing
Flame Shutter
Cause
Improper circuit current rating
Remote control has a similar
frequency to other remotes in
the area
Radio frequency disturbance
from outside sources
Unit is drawing close to circuit
current rating
Normal operation
Defective power cord
Cause
Improper operation
Defective main on/off switch
Defective remote control
Loose wiring
Defective flame motor
Loose wiring
Burnt light bulbs
Loose wiring
Defective light harness
Burnt light bulbs
Defective flame motor
18
Solution
Additional appliances may
exceed the current rating of
the circuit breaker or fuse.
Plug unit into another outlet
or install unit on a dedicated
15 amp circuit
Select alternative frequency
code
Move the unit to another
outlet or install unit on a
dedicated 15 amp circuit
The power cord may get
slightly warm to the touch
when the heater is on
Replace power cord
Solution
Refer to User's Guide
Replace main on/off switch
Install new batteries into the
handheld transmitter /
reinitialize
Check wiring connections
Replace flame motor
Check wiring connections
Replace light bulbs
Check wiring connections
Replace light harness
Replace light bulbs
Replace flame motor
Service Manual
Reference
Page 1
Page 16
Service Manual
Reference
Page 10
Page 1
Page 7
Page 12
Page 7
Page 8
Page 7
Page 8
Page 12