To Replace The Circuit Board - Dimplex SF3202 Service Manual

Hide thumbs Also See for SF3202:
Table of Contents

Advertisement

SF3202
If unit was operating prior to servicing allow at least 10 minutes for light bulbs and
heating element to cool off to avoid accidental burning of skin.
Disconnect power before attempting any maintenance or cleaning to reduce the risk of
electric shock or damage to persons.

TO REPLACE THE CIRCUIT BOARD

1. Remove the firebox from the back of the mantel.
2. Remove the retaining screws on the top panel and remove the top being careful not
to damage any of the wiring.
3. Locate the circuit board mounted on the side panel and disconnect the wiring clips
and connections noting their original locations.
4. Break off the six mounting studs on the flame speed control by grasping with pliers
and twisting on the protruding part of the stud, push the remainder of the studs out
through the top panel.
NOTE: New mounting studs are supplied with the replacement speed control.
5. Properly orientate the new circuit board and connect all of the wiring connections.
6. Reassemble in the reverse order as above.
16