OPERATION RANGES

The table below indicates the temperature and humidity ranges the air conditioner can be operated within.
Refer to the table for efficient use.
OPERATIONAL TEMPERATURE
MODE
INDOOR
COOLING
18˚C to 32˚C
HEATING
27˚C or less
DRYING
18˚C to 32˚C
The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below,
the heating capacity can be reduced depending on the temperature condition.
If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.
INDOOR HUMIDITY
OUTDOOR
15˚C to 43˚C
80% or less
-5˚C to 24˚C
-
15˚C to 43˚C
-
IF OUT OF CONDITIONS
Condensation may occur on
the indoor unit with risk to have
either water blow off or drops on
the floor.
Internal protection triggers and
the air conditioner will stop.
Condensation may occur on
the indoor unit with risk to have
either water blow off or drops on
the floor.