Service And Adjustments - Craftsman 919.167630 Owner's Manual

Permanently lubricated, single stage, portable
Hide thumbs Also See for 919.167630:
Table of Contents

Advertisement

Available languages

Available languages

Risk of unsafe
operation. Unit
cycles automatically when power is
on. When doing Maintenance, you
may be exposed to voltage sources,
compressed air or moving parts.
Personal injuries can occur.
Before servicing:
• Unplug or disconnect
electrical supply to the air
compressor.
• Bleed tank of pressure.
• Allow the air compressor to
cool.
ALL MAINTENANCE AND REPAIR
OPERATIONS NOT LISTED MUST
BE PERFORMED BY TRAINED
SERVICE TECHNICIAN.
TO REPLACE CHECK VALVE
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug outfit.
3.
Remove the shroud on the outlet
tube side. NOTE: Remove screw
with T-20 Torx screwdriver and
loosen all the tabs on the shroud
with a flat screwdriver before
removing.
4.
Using an adjustable wrench, loos-
en outlet tube nut at air tank and
pump head. Carefully move outlet
tube away from check valve.
1000002924

SERVICE AND ADJUSTMENTS

5.
Using an adjustable wrench
loosen pressure relief tube nut at
air tank. Carefully move pressure
relief tube away from check valve.
Pressure
Relief
Tube
Check
Valve
6.
Unscrew the check valve (turn
counterclockwise) using a 7/8"
open end wrench. Note the orien-
tation for reassembly.
7.
Install the new check valve (turn
clockwise).
8.
Replace the outlet tube and tight-
en nuts.
9.
Replace the shroud.
10. Replace the outlet tube and tight-
en nuts.
11. Perform the Break-in Procedure.
See "Break-in Procedure" in the
Operation section.
TO REPLACE REGULATOR
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug compressor.
3.
Remove the regulator ring and
remove the console cover.
Regulator
Ring
18- ENG
Outlet
Tube
Nuts
Cover