HP ProLiant DL370 Generation 6 Overview page 56

Expandable tower chassis/4u rack optimized chassis
Hide thumbs Also See for ProLiant DL370 Generation 6:
Table of Contents

Advertisement

QuickSpecs
Technical Specifications
System Inlet
Temperature
Relative Humidity
(non-condensing)
Altitude
Acoustic Noise
Emissions Classification
(EMC)
DA - 13242 Worldwide — Version 58 — February 27, 2013
Operating
Non-operating
Operating
Non-operating
Operating
Non-operating
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in accordance
with ISO 9296 (ECMA 109).
Idle
L WAd
L pAm
Operating
L WAd
L pAm
NOTE: The Listed sound levels apply to standard shipping configurations.
Additional options may result in increased sound levels.
FCC Rating
Normative Standards
HP ProLiant DL370 Generation 6 (G6)
HP ProLiant ML370 Generation 6 (G6)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
10 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
4.6 B for 1P Non-Redundant; 4.9 B for 2P
Redundant
28 dB for 1P Non-Redundant; 31 dB for 2P
Redundant
4.7 B for 1P Non-Redundant; 5.0 B for 2P
Redundant
29 dB for 1P Non-Redundant; 32 dB for 2P
Redundant
Class B
CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15;
ICES-003; CNS13438; GB9254; K22;K24; EN
61000-3-2; EN 61000-3-3; EN 60950-1; IEC
60950-1
Page 56