MAINTENANCE
Lights
NOTE:
Turn off the lights and fan. Allow the lights
to cool before handling.
If new lights do not oper-
ate, be sure lights are inserted correctly before
calling for service.
Halogen Light Replacement
Using a flat edge from a screwdriver or equiva-
lent tool, pry loose the lens cover as shown in
Figure 4.
Remove the damaged light and replace with a
new 12 Volt, 20 Watt (maximum) halogen light
made for a G-4 base. Follow package direc-
tions and do not touch new light with bare
hands.
Reinstall the light and cover.
Heat Lamp Replacement
Turn heat lamp counterclockwise
to remove.
Replace lamp with either a PAR-38 175W heat
lamp or a PAR-40 250W heat lamp.
The PAR-38 175W heat lamp provides a tighter seal
within the enclosure and produces the same amount
of effective heat with lower energy consumption.
These lamps may not be readily available at local
retail outlets. The PAR-40 250W heat lamp is more
widely available. It can be used instead.
PAR-38 175W heat lamps can be purchased through
the following retailers:
• OpTech Inc: 800-848-6624
• bulbs.com: 888-455-2800 or www.bulbs.com
Figure 4
CAUTION
Do not touch the bulbs immediately
after use.
The bulbs will remain hot for several minutes. Do
not place highly flammable material on warming
shelves.
Figure 5