CALIBRATING THE DISPENSER

CALIBRATION MODE: The SLCA-7 is calibrated at the factory and does not normally need to be re-calibrated.
To enter the Calibration Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position and then hold
the MENU switch down for 10 seconds.
LED DISPLAY
C
1
r u n
MENU
(-)
C
1
3.
4 0
MENU
(-)
C
2
r u n
MENU
(-)
C
2
4
3.
MENU
(-)
C
3
r u n
MENU
(-)
C
3
.4
1
MENU
(-)
CALIBRATION MODE
Left Pump Cal.
(+)
Left Pump Cal.
(+)
Right Pump Cal.
(+)
0
Right Pump Cal.
(+)
Left Coffee Water Rate
(+)
4
Left Coffee Water Rate
(+)
DESCRIPTION
Set PRIME-NORMAL-RINSE switch
to PRIME position.
Press the SMALL button, left pump
will run for 100 counts
Enter ml collected from the 100 count
test above.
Default = 43.0 ml
Set PRIME-NORMAL-RINSE switch
to PRIME position.
Press the LARGE button, left pump
will run for 100 counts
Enter ml collected from the 100 count
test above.
Default = 43.0 ml
Set PRIME-NORMAL-RINSE switch
to RINSE position
Press the SMALL button, left pump
dilution water will run for 20 seconds.
Enter Liters collected from 20 sec.
test above
Default = .414
18