Listing and Code Approvals
A. Appliance Certifi cation
MODEL
Tiara I B
LABORATORY OMNI-Test Laboratories, Inc.
061-S-43b-5
TYPE
Vented Gas Fireplace Heater
STANDARD
ANSI Z21.88-2002
UL307b
MODEL
Tiara II B
LABORATORY OMNI-Test Laboratories, Inc.
061-S-44b-5
TYPE
Vented Gas Fireplace Heater
STANDARD
ANSI Z21.88-2002
UL307b
The product is listed to ANSI standards for "Vented Gas
Appliance Heaters" and applicable sections of "Gas Burning
Heating Appliances for Manufactured Homes and Recre-
ational Vehicles" and "Gas Fired Appliances for use at High
Altitudes".
Manufactured Home or Mobile Home installation may occur
only after the home is site located and must conform with
the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, or, when such a standard is
not applicable, the Standard for Manufactured Home
Installations, ANSI/NCSBCS A225.1, or Standard for Gas
Equipped Recreational Vehicles and Mobile Housing, CSA
Z240.4.
When installed, the appliance must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
B. Glass Specifi cations
This appliance is equipped with 5mm ceramic glass behind
the curved glass. Replace glass only with 5mm ceramic
glass. Please contact your dealer for replacement glass.
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A.
and the CAN/CGA B149 Installation Codes in Canada.
Page 4
ּ
CSA 2.33-2002
ּ
CAN/CBA 2.17-M91
ּ
CSA 2.33-2002
ּ
CAN/CBA 2.17-M91
Heat & Glo · Tiara I B & Tiara II B · 7010-149M
C. Specifi cations
Model
Maximum
Minimum
Input
Input
(US or Canada)
BTU
BTU
Tiara I B
31,000
22,000
(NG)
Tiara I B
30,000
23,000
(LP)
Model
Maximum
Minimum
Input
Input
(US or Canada)
BTU
BTU
Tiara II B
38,500
27,000
(NG)
Tiara II B
39,000
30,500
(LP)
*Maximum Vent Blower On
D. High Altitude Installations
Omni-Test Laboratories, Inc. listed gas appliances are tested
and approved without requiring changes for elevations from 0
to 2000 feet in the U.S.A. and 0 to 4500 feet in Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating by
changing the existing burner orifi ce to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above a
2000 foot elevation in the U.S.A. If the heating value of the
gas has been reduced, these rules do not apply. To identify
the proper orifi ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 feet (in
Canada), check with local authorities.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
E. Non-Combustible Materials
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a Vertical
Tube Furnace at 750°C, shall be considered non-combustible
materials.
F. Combustible Materials
Materials made of or surfaced with wood, compressed
paper, plant fibers, plastics, or other materials that can ignite
and burn, whether flame proofed or not, or whether plastered
or unplastered shall be considered combustible materials.
Orifi ce
*Steady
**P.4
Size
State
%
Effi ciency
%
.106
81.43
57.33
.063
82.75
56.39
Orifi ce
*Steady
**P.4
Size
State
%
Effi ciency
%
.120
81.36
60.97
.073
83.62
64.14
**Canada Only
August 1, 2008