Section 6: Gas Information; Fuel Conversions - Heat & Glo TIARA I-B Owner's Manual

Tiara i-b, tiara ii-b direct vent room heater
Table of Contents

Advertisement

6
Gas Information
A. Fuel Conversions
Before making gas connections ensure that the appliance
being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to meet
the appliance and locality needs must be made by a qualifi ed
technician using Hearth & Home Technologies specifi ed and
approved parts.
1. Converting to LP Gas
NOTE: Gas conversions should only be performed
by a qualified service person, and/or where required
by state and local codes, licensed installer/service
technician. In the Commonwealth of Massachusetts,
installation must be performed by a licensed plumber
or gas fitter.
KIT CONTENTS:
Replacement orifi ce; replacement
pilot injector; valve regulator; conversion label.
TOOLS REQUIRED: Power drill (a 90° handle is help-
ful); #2 Phillips bit; 7/16" wrench,. slotted screwdriver
or Torx TH20, 5/32 in. Allen wrench, 5/8 in. open end
wrench,
Remove front (if installed), glass, and logs (if installed.)
Tiara I-B Burner Removal:
Figure 6.1
Remove the optional brick set, if installed. Remove
the two screws, one on each side of burner. Retain fasteners
for reinstallation. Lift burner up and out of the fi rebox.
Page 24
Tiara II-B Burner Removal:
Figure 6.2
(2) 1/4" x 20 screws securing the burner as indicated. Lift
burner out of fi rebox.
Figure 6.3
screw on the pilot tower, and removing the three screws on
the front side of the burner neck support.
Slide the burner neck support to the left.
Heat & Glo · Tiara I B & Tiara II B · 7010-149M
Using the #2 Phillips screwdriver remove the two
Remove the burner support by loosening the left
August 1, 2008

Advertisement

Table of Contents
loading

Table of Contents