Optional Blower - Heat & Glo TIARA I-B Owner's Manual

Tiara i-b, tiara ii-b direct vent room heater
Table of Contents

Advertisement

M. Optional Blower
KIT CONTENTS: Blower; speed control; lock nut; control
knob; ground clip; temperature sensor switch; wing nut; 2
high-temp black wires; 1 high-temp blue wire.
TOOLS REQUIRED: Philips head screwdriver; 1/2 in.
wrench.
The GFK-160A blower has been designed to circulate room
air through the appliance to enhance heat output.
The blower system operates on 120 VAC, 60 Hz power. This is
available through a receptacle in the factory installed junction
box on the underside of the appliance.
BLOWER
CONTROL
KNOB
GROUND
CLIP
CONTROL
NUT
SPEED
CONTROL
Figure 8.26
Compare CONTENTS OF CARTON with the
actual parts received. If any parts are missing or damaged,
contact your dealer before starting installation. Do not install
a damaged blower kit.
Figure 8.27
From the rear of the appliance, slide the blower
into the blower housing with the magnetic strips down. The
blower openings should be at the front.
Plug blower power cord into fan outlet on junction box.
August 1, 2008
WING
NUT
TEMP.
SENSOR
SWITCH
Heat & Glo · Tiara I B & Tiara II B · 7010-149M
Figure 8.28
Attach grounding clip supplied with the kit to the
blower housing. Attach ground wire to grounding clip.
WING NUT
Figure 8.29
Slide temperature sensor switch/bracket assembly
onto the 10-32 screw located on the left underside of the
appliance. Secure the bracket assembly with the wing nut
provided.
Disconnect the two wire ends connected together on the
junction box. Connect female end to one side of temperature
sensor switch.
Connect one end of the black wire provided with the kit to the
remaining wire end on junction box.
Feed loose ends of the black and blue wires through the
orange grommet in fan housing.
SCREWS
Figure 8.30
Remove valve access cover from back of
appliance by removing the three screws indicated.
3