Figure 4.3: Alarms and Warnings Monitoring Window
In this window each of the properties listed may be monitored on two levels - alarm or warning.
The thresholds of some of these properties are adjustable by the user. The Status column shows
that the 'Fan Fault' alarm status is satisfactory i.e. warning monitoring is not being performed for
this property, and that 'Board Temp' alarm and warning monitoring are also satisfactory.
An example is given below to illustrate the process of applying monitoring to other properties on
the window.
To apply 'Fan too fast' monitoring to fan number 2:
1.
Check the Alarm and Warning boxes in the appropriate row of the window shown above.
2.
Check the 'Monitor Fan 2' box.
3.
Select the 'Update Monitor' tab on the top right-hand side of the window. A window similar
to the one shown in Figure 4.4 is displayed.
SBD75e Series Demodulator Installation and Operation Manual
Web GUI Monitoring & Control
4-5