MIL-3000FTX Series of FastPort™ Print Servers Hardware User’s Guide with FastManage™ -Specific Information Sunnyvale, California Minnetonka, Minnesota...
Table of Contents Preface About this Manual ....................P-1 FastPort Documentation ..................P-1 Contents of this Document................. P-2 Notation Conventions ..................P-2 Chapter 1: Introduction Overview of the MIL-3000FTX Print Servers........... 1-1 Features of the Print Servers ................1-2 Physical Features ..................1-2 Configuration Features ................
Page 4
Appendix B: Technical Support Services World Wide Web Server..................B-1 Internet FTP Server....................B-1 Contacting Technical Support ................B-2 Expediting Technical Support Service.............. B-2 Returning Procedures ..................B-2 Index MIL-3000FTX Series of FastPort Print Servers...
P reface About this Manual This manual has instructions on how to physically install the MIL-3000FTX series of FastPort print servers. This document also has specific information on the FastManage™ suite of software as it applies to the MIL-3000FTX series. The terms “MIL-3000FTX,”...
• Chapter 3: This section has information on FastManage for the MIL-3000FTX • Appendix A: Has specifications information • Appendix B: Provides technical support information, including how to contact Digi Notation Conventions This document has certain notation conventions that make it easier to follow instructions and examples. Notation conventions used in this manual are shown in Table P-1.
Ethernet and/or Fast Ethernet networks. Versions of the print servers include: • MIL-3100FTX: One RJ-45 (UTP), 10/100 Mbps port; one parallel port and one serial port • MIL-3200FTX: One RJ-45 (UTP), 10/100 Mbps port; two parallel port and one serial port •...
Chapter 1 1.2 Features of the Print Servers 1.2.1 Physical Features Physical features for the MIL-3000FTX FastPort includes: • 10/100BASE-TX, RJ-45 connector • Centronics compatible parallel ports • RS-232 serial port • Diagnostic LEDs • Four position DIP switch 1.2.2 Configuration Features Configuration features for the MIL-3000FTX include: •...
The MIL-3000FTX also supports SNMP MIB-II (RFCs 1213) and parallel/serial MIBs (RFCs 1318 and 1317). 1.3 Utilities To make the units easier to manage, Digi supplies the FastManage suite of software and the Advanced Configuration Tool™ (ACT). FastManage is a windows-based menu software application and ACT is a DOS-based menu software application.
Page 10
Chapter 1 MIL-3000FTX Series of FastPort Print Servers...
• Four rubber feet to keep the print server from sliding. These are also included in the packaging Contact Digi LAN technical support (see Appendix B) if you are missing an item(s) from the packaging. MIL-3000FTX Series of FastPort Print Servers...
FastPort 10/100 Mb/s PRINT SERVER LNK NET SYS SER PWR Figure 2-1. MIL-3100FTX Front Panel Note: The MIL-3200FTX will have one extra LED: “P2.” The MIL-3310FTX will have two extra LEDs: “P2” and “P3.” MIL-3000FTX Series of FastPort Print Servers...
Page 13
Chapter 2 Switch Position Mode Description Flash Selects bank 0 (upper) to run the 4 Mb Flash EPROMs for Bank uploading the new firmware image. Down Selects bank 1 (lower) to run the 4 Mb Flash EPROMs for uploading. If the upgrade process fails, use this setting and power cycle the unit to return FastPort to its default settings.
Page 14
Chapter 2 Rear POWER PARALLEL 1 Figure 2-2. Rear Panel of MIL-3100FTX Note: The MIL-3200FTX will have two parallel ports. The MIL-3310FTX will have three parallel ports. 8. Connect the power supply: Select the proper voltage for the specific country.
C h a p t e r 3 FastManage for the MIL-3000FTX FastPort Chapter 3 discusses FastManage-specific software, though, only as it applies to the MIL-3000FTX series of print servers. This chapter does not have detailed instructions. Refer to the FastManage User’s Guide for installation and configuration information on the FastManage suite of software.
Page 16
Chapter 3 Figure 3-1. FastManage for FastPort b. Icons will now appear on Map 1 as “thumbnails,” each represent an SNMP device. c. Double-click on a thumbnail to display a full-screen image of a particular SNMP device (Figure 3-2). • FastPort PrintServer Mgr. Icon: a.
The “Auxiliary Port” sub-menu (Figure 3-3) differs from each FastPort because of the number of parallel ports, for example: • The MIL-3100FTX has information for one Serial port and one Parallel port • The MIL-3200FTX has information for one Serial port and two Parallel ports •...
Chapter 3 To view the “Auxiliary Port” sub-menu from the “Configuration” pull-down menus, go to: TCP/IP Config.--> FPFILTER Configuration-->Auxiliary ports Figure 3-3. Auxiliary Port Sub-Menu: MIL-3310FTX This parameter specifies an auxiliary port for parallel or serial port printing. 3.3.2 Parallel Printer Setup Sub-Menu Again, the “Parallel Printer Setup”...
Chapter 3 Figure 3-4. Parallel Printer Setup Menu This parameter sets-up the port for parallel port printing. Hot Spots Hot spots on the graphical representation of a MIL-3000FTX graphic (Figure 3-2) are used to gain status of the device. Use the mouse to highlight the selection (a block around the area appears), and click on it to obtain the information.
Page 20
Chapter 3 • Digi/MiLAN logo: Depending on the versions of MIL- 3000FTX, either a “MiLAN” or a “Digi” appears on the top, right-hand side of the graphic. When this Logo is clicked on, FastPort specifications appear. Change the Name, Location, and Contact and press Set (Figure 3-5).
A p p e n d i x A S pecification s A.1 Resetting FastPort Back to the Factory Defaults 1. Place the front panel switches: D3 and D4 down. 2. Unplug then plug back in the power supply. 3. Wait at least 4 seconds. 4.
Appendix A • Flash: Flash devices are 29F040. Each device is 4 Mbps and arranged in 2 256k 8 format. • MAC chipsets: Ethernet controller is 10/100 Mbps, with its own memory management • 10/100BASE-TX, RJ-45 (unshielded twisted pair) connector A.3 Serial Printer and Terminal Cables Print Server Side...
Appendix A DB9 Female DB25 Male FastPort Side Terminal/Printer Function Pin # Pin # Function SGND SGND Figure A-5.DTE Printer/Plotter and PC Null: DB25 Male DB9 Female DB25 Male FastPort Side Terminal/Printer Function Pin # Pin # Function SGND SGND Figure A-6.DCE Printer/Plotter: DB25 Female A.4 System LEDs Functioned...
Our address is: http://www.dgii.com B.2 Internet FTP Server Digi has set up an anonymous FTP server for those with access to the internet. The address is ftp.milan.com or 206.40.59.2. Log-in as anonymous, and enter an email address when asked for a password.
• Note any and all error messages. • Be specific about the problem(s). B.5 Returning Procedures To return a unit to Digi: 1. Call technical support at 408/744-2751 2. Technical support engineers will work with users to find the problem. If technical support determines that the unit is...