ADC PHASE 6 OPL User Manual page 62

On-premise laundry (opl) drying system
Table of Contents

Advertisement

7. bURNER FLAME FAIL - this routine allows two (2) Flame Out retries to occur before proceeding into
the error. The count of two (2) will be established every time the call for heat was to occur. Only if it
reaches the count of two (2) before the basket (tumbler) temperature has reached the set temperature will
this error triggered. The dryer will run with no heat for 3 minutes or until the temperature drops below 100º
F. If the basket (tumbler) temperature is below 100º F upon failure, the dryer will shut down and display
"bURNER FLAME FAIL" with an audio indication. This process will occur every time the heat output is
active.
8. MAIN dOOR - this monitors the door circuit. If the dryer was not active and the main door was opened
the display would read "REAdY." If a program attempt was made with the main doors open the display
will read "MAIN dOOR" with an audio indication. If the dryer is active and the main door was opened the
display would read "MAIN dOOR" with no audio indication and the dryer will shut down. Once the main
door has closed the display would read "PRESS START" press the "ENTER/START"
continue the programmed cycle.
9. LINT dOOR - this monitors the lint drawer/door circuit. If the dryer was not active and the lint drawer/
door was opened the display would read "REAdY." If a program attempt was made with the lint drawer/
door open the display would read "LINT dOOR" with an audio indication. If the dryer was active and the
lint drawer/door was opened the display would read "LINT dOOR" with no audio indication and the dryer
will shut down. Once the lint door was closed the display would read "PRESS START" press the "ENTER/
START"
Key and it will continue the programmed cycle.
10. TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE - this routine monitors the basket (tumbler)
temperature. When the temperature sensor or fuse opens with the dryer not active the display will read
"TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE" with an audio indication. If the dryer was
active at the time that the temperature sensor or fuse opened the display would read "TEMP SENSOR
FAIL CHECK TEMP SENSOR FUSE." If the basket (tumbler) temperature is above 100º F the dryer will
continue to display "TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE" with an audio indication and
run with no heat for 3 minutes or until the temperature drops below 100º F. If the basket (tumbler)
temperature is below 100º F upon failure the dryer will shut down and display "TEMP SENSOR FAIL
CHECK TEMP SENSOR FUSE" with an audio indication. The display will continue to read "TEMP
SENSOR FAIL CHECK TEMP SENSOR FUSE" an audio indication will sound for approximately
5-seconds, every 30-seconds until the problem is corrected or the power to the dryer is discontinued (and
the problem is corrected).
NOTE: Once the Phase 6 microprocessor controller (computer) detects a problem in the heat circuit, it
updates every 30-seconds, so that if the problem was a loose connection in the circuit which
corrected itself, the "TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE" condition
would automatically be cancelled and the display will return to "REAdY."
11. ROTATE SENSOR FAIL - indicates a rotational sensor circuit failure meaning that there is a fault
somewhere in the basket (tumbler) rotation circuit, or the Phase 6 OPL microprocessor controller (computer)
program related to this circuit (Program Location 2) is set incorrectly. In the active mode it should be
(ROTATE SENSOR ACTIVE), if the dryer is not equipped with the optional rotational sensor it should be
set in the nonactive mode (No ROTATE SENSOR).
59
Key and it will

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents