ADC PHASE 6 OPL User Manual page 19

On-premise laundry (opl) drying system
Table of Contents

Advertisement

c. Spin Time - this parameter (program) is fixed at 3 minutes in Forward 2 minutes in Reverse the Automatic
Mode and programmable in the Manual Mode. This Spin Time is programmable (in the manually loaded
cycle ONLY) from 30-seconds to 120-seconds in one-second increments.
d. Dwell (Stop) Time - this parameter (program) is fixed at 5-seconds in the Automatic Mode and
programmable in the Manual Mode. This Dwell (Stop) Time is programmable (in the manually loaded
cycle ONLY) from 5-seconds to 10-seconds in one-second increments.
e. Buz (Tone) Time - this parameter allows the operator to adjust the time the signal tone sounds from 0 to
15-seconds in one-second increments. This parameter (program) affects the tone at the end of the
drying cycle and cooling cycle, as well as, at the end of the Guard On Time when the Anti-Wrinkle
Program is active.
4. Program Location 0 (Key "0")
a. Lint Count - this feature is preset for dryer model and or application. The register sets the maximum
amount of cycles it will run before being locked out (out of service). The range for lint count is from 0
to 10.
b. Anti-Wrinkle Program Activation - this parameter (program controls whether or not the Anti-Wrinkle
Program will be active (on) for manually loaded cycles ONLY.
c. Buz Time (Anti-Wrinkle Tone) - when the Anti-Wrinkle Program is active, this parameter (program)
allows the operator the option to have the tone (buzzer) sound at the end of each Anti-Wrinkle On Time
cycle. The buz (tone) time is programmable from 0 to 15-seconds in one-second increments (refer to
Program Location 8 [Key "8"]).
d. Anti-Wrinkle On Time - this parameter (program) controls the amount of time that the basket (tumbler)
will turn (spin/rotate) without heat when the Anti-Wrinkle Program is active. The Anti-Wrinkle On
Time is programmable from 10-seconds to 60-seconds in one-second increments.
e. Anti-Wrinkle Delay Time - when the Anti-Wrinkle Program is active, this parameter (program) controls
the Dwell (Stop) and activation of the Anti-Wrinkle On Time. The Anti-Wrinkle Delay Time is
programmable from 10-seconds to 255-seconds in one-second increments.
f. Maximum Guard On Time - this parameter (program) controls the maximum time that the Anti-Wrinkle
Program will be in progress. The Maximum Guard On Time is programmable from 1 minute to 99
minutes in one-minute increments.