B. SYSTEM PARAMETERS (PROGRAM LOCATIONS)
1. Factor "A" (Slope) from 1 to 9 in increments of one (1).
2. Factor "b" (Heat Loss - Offset) from 1 to 99 in increments of one (1).
3. Manual Selection Auto Mode ("COOL TIME") from 0 to 99 minutes in one-minute increments.
4. Maximum Guard Time ("MAX ANTI WRINKL GUARd TIME") from 1 minute to 99 minutes in
one-minute increments.
5. Guard On Time ("ANTI WRINKL GUARd ON TIME") from 10 to 60-seconds in one-second increments.
6. Guard Delay Time ("ANTI WRINKL GUARd dELAY TIME") from 10 to 255-seconds in one-second
increments.
7. Buzz (Tone) Time ("bUZZ") from 0 to 15-seconds in one-second increments.
8. Flash Display Cycle/Time ("FLASH") 15-seconds.
9. Flash Display Temperature/Time ("dRY TEMP") 1-second.
10. Lint count can be set from (1-10) drying cycles. The routine will first prompt the user "REAdY CLEAN
LINT" two (2) drying cycles prior to the dryer locking the operator out. The "CLEAN LINT" displays
when the dryer is in a locked out state. This will not be cleared until the lint drawer has been cleaned. Then
the dryer will return to its operating function.
C. FIXED PARAMETERS
1. Spin Time ("SPIN TIME") is fixed at 180-seconds in forward and 120-seconds in reverse.
2. Stop (Dwell) Time ("STOP TIME") is fixed at 5-seconds (in the Auto Mode) and is not adjustable.
55