Enclosure Unit – Tower
Enclosure Unit – Tower
Enclosure Unit – Tower
Enclosure Unit – Tower
Model
Model
Model
Model
System Inlet Temperature
System Inlet Temperature Operating
System Inlet Temperature
System Inlet Temperature
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Altitude
Altitude
Altitude
Altitude
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Dimensions (H x W x D)
Dimensions
Dimensions
Dimensions
(with bezel)
Weight
Weight
Weight
Weight
(approximate)
DA - 12790
North America — Version 7 — February 11, 2008
Non-operating
Operating
Non-operating
Operating
Non-operating
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
Idle
Operating
21.29 x 13.48 x 34.43 in (54.08 x 34.24 x 87.45 cm)
Maximum
(all server blades and
interconnects installed)
Minimum
(2 power supplies & 4
fans, no server blades nor
interconnects installed)
HP BladeSystem c3000 Enclosure
HP BladeSystem c3000 Enclosure
HP BladeSystem c3000 Enclosure
HP BladeSystem c3000 Enclosure
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
depends on server configuration & mix of server
blades
varies by CPU utilization, server configuration,
and mix of server blades
342 lb (155 kg)
192 lb (87.09 kg)