Installation; Uncrating; Location; Installation Codes And Standards - Vulcan-Hart GRC 35 Installation & Operation Manual

Grc series gas fryers
Hide thumbs Also See for GRC 35:
Table of Contents

Advertisement

INSTALLATION

Before installing the fryer, verify that the type of gas (natural or propane) agrees with the specifications on the
fryer data plate which is located on the inside of the door panel. Also be sure the unit is built for the installation
elevation.

UNCRATING

This fryer was carefully inspected before leaving the factory. The transportation company assumes full
responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking the fryer, check
for possible shipping damage. If the fryer is found to be damaged, save the packaging material and contact the
carrier within 15 days of delivery.
Do not use the door or its handle to lift or move the fryer.

LOCATION

The equipment area must be kept free and clear of combustible substances.
Minimum clearance from combustible and non-combustible construction is 6" (15 cm) from the sides and
6" (15 cm) from the back of the fryer. There must be at least 16" (40.6 cm) clearance between the fryer and any
open top flame units. Adequate clearances for servicing and proper operation must be allowed. The unit may
be installed on combustible floors.
Install the fryer in an area with sufficient air supply for combustion of the gas at the fryer burners. Provide
adquate clearance for air openings into the combustion chamber. Do not obstruct the flow of combustion and
ventilation air.
Do not permit fans to blow directly at the fryer. Avoid open windows next to the sides or back. Avoid wall-type
fans which create air cross currents within the room.

INSTALLATION CODES AND STANDARDS

In the United States of America:
Vulcan-Hart fryers should be installed in accordance with state and local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI-Z223.1 (latest edition), available from American Gas Association, Inc.,
1515 Wilson Boulevard, Arlington, VA 22209, and with ANSI-NFPA Standard #96 (latest edition), Vapor
Removal from Cooking Equipment, available from the National Fire Protection Association, Batterymarch Park,
Quincy, MA 02269.
In Canada:
Vulcan-Hart fryers should be installed in accordance with local codes, and CAN/CGA-B149.1 Installation for
Natural Gas Burning Appliances and Equipment (latest edition), or CAN/CGA-B149.2 Installation for Propane
Burning Appliances and Equipment (latest edition). Copies may be obtained from The Canadan Gas
Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.

ASSEMBLY

The fryer must be restrained with adequate ties to prevent tipping when installed in order to avoid the splashing
of hot liquid.

Legs

Position fryer in an open space near the final installation area. Tilt fryer on its side, being careful to avoid
scratching the finish. Thread legs into mounting holes provided on bottom of fryer by screwing in a clockwise
rotation until tight.