13
13

Finishing

A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Mantels
8
7
6
5
4
13-1/4
3
12-1/2
11-3/4
11
10-1/4
6
Measured from top of hood (in inches)
Figure 13.1 Minimum Vertical and Maximum Horizontal Dimen-
sions
Mantel Legs or Wall Projections
Top of
Appliance
A
1 in. (25 mm) min.
to perpendicular wall
B
3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall
Figure 13.2 Mantel Leg or Wall Projections (Acceptable on both
sides of opening)
30 in. minimum
to ceiling
18
17
16
20-3/4
15
20
14
13
19-1/4
12
18-1/2
11
17-3/4
10
17
9
16-1/4
15-1/2
14-3/4
14
Drywall
A
B
Mantel Leg or
Perpendicular Wall
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 11/08
B. Facing Material
Metal front faces may be covered with non-combustible
materials only.
Facing and/or fi nishing materials must not interfere with
air fl ow through louvers, operation of louvers or doors,
or access for service.
Facing and/or fi nishing materials must never overhang
into the glass opening.
Observe all clearances when applying combustible
materials.
Seal joints between the fi nished wall and appliance top
and sides using a 300 °F minimum sealant. Refer to
Figure 13.3.
WARNING! Risk of Fire! DO NOT apply combustible ma-
terials beyond the minimum clearances. Comply with all
minimum clearances to combustibles as specifi ed in this
manual. Overlapping materials could ignite and will inter-
fere with proper operation of doors and louvers.
Finish wall material may be
combustible - Top and Sides
0 in.
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
Figure 13.3 Noncombustible Facing Diagram
0 in.
0 in.
59