SET Set Temperature Button
Button Press: Displays Set Point
Use UP and Down Arrows to adjust set point
Press Set Button to store new set point
Temperature Set Point can be adjusted between the rang-
es of 45-90° Fahrenheit or 7-32° Centigrade.
Note: The controller will turn off the fi replace at 2° F over
set point and turn it back on at 2° F below set point.
Up and Down Arrows
Push to adjust set point temperature under automatic
control.
AUX
Auxilary Button
Button Press: Turns on auxilary power
Button Press: Turns off auxilary power
Can be operated independently of all functions.
Child Proof Mode
To Enter Child Proof Mode:
Press the Up Arrow Button twice and Down Arrow Button
once. The unit will send out three beeps and an indicator
in the LCD panel will show that the child proof is on.
To Leave Child Proof Mode:
Press the Up Arrow Button twice and Donw Arrow
Button once. The unit will send out three beeps and the
indicator in the LCD panel showing that child proof is on
will disappear.
Note: When in Child Proof Mode, only the arrow buttons
will have functionality. Unit can enter Child Proof when
the fi replace is on or off.
Cold Climate Button
Button Press: Turns on Climate Control
Button Press: Turns off Climate Control
This allows the pilot fl ame to stay lit when activated. A
benefi t of this is reduced condensation on the glass at
start-up in colder climate conditions.
58
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 11/08
Operation Under Battery Power
A switch on the control box allows for battery power
under no-power conditions (see Figure 12.9). By control-
ling the power supply with this switch, the batteries are
supplying power only when needed, thus extending bat-
tery life. The switch also provides a convenient means for
switching to battery power should there be a loss of 110
VAC power to the control box.
In the event of a power failure, switch the battery
operation switch to the "Battery ON" position.
The fi replace can now be turned on and off with the
ON/OFF rocker switch located near the gas valve.
The wall switch functions will not operate under battery
power.
Under battery control the only available function is fl ame
"ON" and "OFF" in the high position.
To maximize battery life, and to restore full function
capability of the wall switch, fl ip switch to "OFF" position
after 120 VAC power is restored.
Battery
Operation
Switch
Control
Box
"OFF"
Position
Figure 12.9 Control Box

Service Parts List

Description
Solenoid
Wall Switch/Key Pad
Cover Plate
Control Box
Actuator Pins
Switch Kit
Wire Assy Male Terminals
Wire Assy 1-Male/1-Female Terminal
"Battery On"
Position
Service Part #
HTI-17-006
HTI-12-007
HTI-21-007
HTI-13-007
HTI-17-116
060-511
4003-128
4003-129