D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing or fi nishing material closer than
the minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc).
Combustible Mantels
NON-COMBUSTIBLE
MATERIAL ONLY
1/2 INCH
(13 mm)
Figure 5.3 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. N • 11/08
CEILING
12 IN.
(305 mm)
32 IN.
(813 mm)
13 IN.
(330 mm)
TOP FRONT EDGE OF FIREPLACE
TOP OF HOOD
Combustible Mantel Legs or Wall Projections
TOP VIEW
Note: Clearance from opening
to perpendicular wall.
Figure 5.4 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
1 in.
MIN.
3 in.
MIN.
3 ft.
MAX.