QUICK START

Read this section if you want to install and operate the RPE 228d without wading through the detailed descriptions in
this manual. If the control software has not yet been installed on your computer, refer to SOFTWARE OPERATION on
page Manual-5 first.
Turn the amplifier(s) down or off until all connections are complete. Connect balanced audio INPUTS and OUTPUTS
to the handy Euroblock connectors on the rear. Connect the RW 232 INPUT jack on the rear to a serial (COM) port on a
PC-compatible computer using a standard 9-pin RS-232 cable (a short one is supplied with the unit, which is intended to
connect between units in a rack). The cable or adaptor must not be a null-modem type.
Locate the RW 232 DEVICE ADDRESS switch on the rear panel. If this unit is to be tested by itself, set it to '1' by
setting all switches off (down), except switch one (labeled '1' on the chassis, the right-most switch). If there is more than
one unit, refer to SETTING THE DEVICE ADDRESS to set a unique number (see page Manual-4).
Apply power by connecting the RS 1 remote power supply to the red telephone-style jack on the rear of the unit.
CAUTION: don't connect anything but an approved RANE power supply to this jack. If the RS 1 and the RPE 228d are
getting power, the front panel yellow POWER light will be on.
Start your computer, run Windows
Setup window may appear. If it doesn't, select System Setup from the Setup menu. Be careful to select the COM port
which is physically connected to the RPE 228d. Click OK. Now, the Device Selection window may appear. If it doesn't,
choose Select from the Device menu. Click on Poll, ... and the Devices Found will display the number of units found.
Click the Stop button. Select the unit listed in the Device Selection window and click OK. If no unit was found, please
refer to the TROUBLESHOOTING section.
Several clues indicate communication between the computer and the RPE 228d. The yellow COM (communications)
light on the unit should flash periodically. The Memory numbers (1-16) near the top of the computer screen should be
black rather than grey. Clicking the BYPASS button on the screen causes one Channel of the unit to enter Bypass mode.
WEAR PARTS: This product contains no wear parts.
Windows is a registered trademark of Microsoft Corporation.
RaneWare is a registered trademark of Rane Corporation
®
, and launch our software by double-clicking on the RaneWare
PROGRAMMABLE EQUALIZER
RPE 228d
®
icon. The System
Manual-1

Advertisement

Table of Contents
loading

Summary of Contents for Rane RPE 228D

  • Page 1: Quick Start

    Apply power by connecting the RS 1 remote power supply to the red telephone-style jack on the rear of the unit. CAUTION: don’t connect anything but an approved RANE power supply to this jack. If the RS 1 and the RPE 228d are getting power, the front panel yellow POWER light will be on.
  • Page 2: Front Panel Description

    The RPE 228d requires a Rane RS 1 (provided with each To control the units from a computer, use nine-pin RS-232 unit) or compatible power supply. There are #6-32 screws cables which are 50 feet or shorter.
  • Page 3: Rear Panel Description

    REAR PANEL DESCRIPTION Remote POWER jack is for connection to a Rane RS 1 or compatible power supply. Units with outboard power supplies do not ground the chassis through the line cord. Make sure that these units are grounded either to another chassis which is earth grounded, or directly to the grounding screw on an AC outlet cover by means of a wire connected to a screw on the chassis with a star washer to guarantee proper contact.
  • Page 4: Setting The Device Address

    ‘1’ and ‘2’ yields address ‘3’. In the following table, 0 means switch down (OFF), 1 means switch up (ON), and the left-most digit corresponds to the switch labeled ‘128’. Rane provides a special calculator to assist in setting the dip switches on the back of each unit. In the RaneWare program group or folder, launch the RaneWare Address Calculator.
  • Page 5: Software Operation

    RPE connected, you can still use RaneWare offline. After • RaneWare can be fully demonstrated and used without an selecting the RPE 228d, the Graph Editing window appears. actual RPE 228d attached. • A RaneWare 3½" floppy comes with each unit. Installation is simple and follows standard procedure with Windows.
  • Page 6 228d. While Local Edit is selected, clicking on any of the Memory buttons displays the preview curve without recalling it in the RPE 228d. The Device button brings up a selection menu of offline Devices and channels can also be given custom names, devices and the first 15 RaneWare units connected to the tailored to your installation.
  • Page 7 Password Security System > Site Control Panel Setup The RPE can be operated on a daily basis either through a Presets can be customized with names, through System > computer or through the contact closures. To preserve preset Site Control Panel Setup. Here each Memory can have a security with a computer operator, the software can be locked logical name.
  • Page 8: Troubleshooting

    A star washer guarantees proper contact. For more information on balanced interconnection and grounding, please refer to RaneNote 110, “Sound System Interconnection”(next section). ©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 TEL (425)355-6000 FAX (425)347-7757 WEB http://www.rane.com Manual-8 103059...

Table of Contents