Ranging Not Complete

Description
After the cable modem finds the CMTS downstream channel and upstream
parameters, it starts the ranging and automatic adjustments stage. This stage adjusts
the timing offset and the power level for communication with the CMTS.
Note: For more information on this process, see Adjust Timing Offset and Power
Level (on page 9).
The following table illustrates the status of the front-panel LED status indicators
when the ranging not complete condition exists.
LED
1
2
3
4
5
6
7
8
Check and Correct
1
Using the Web browser on the PC attached to the cable modem, access the
WebWizard by entering the following IP address: http://192.168.100.1. The Web
browser accesses the WebWizard and the Default Page opens.
2
Select the Signal page and verify that the cable modem locks to the downstream
channel of the CMTS.
3
Check the upstream power level and the Signal-to-Noise ratio to verify if it is
outside of the operating range.
72-4017315-01 Rev B
Label
Status
POWER
ON
DS
ON
US
BLINKING
ONLINE
OFF
LINK
ON or BLINKING
TEL 1
OFF
TEL 2
OFF
BATTERY
ON WHEN BATTERY IS CHARGED
BLINKING WHEN BATTERY CHARGE IS
LOW
OFF WHEN BATTERY NEEDS TO BE
REPLACED (IF OBSERVED WITH AC
POWER APPLIED TO THE MODEM)

Ranging Not Complete