Clamp Meter
Specifications
Specifications

Electrical Specifications

AC Current (Jaw)
Range ..................................................... 999.9 A
Resolution ............................................... 0.1 A
Accuracy ................................................. 2.0 % 5 digits (45 Hz to 65 Hz)
2.5 % 5 digits (65 Hz to 400 Hz)
AC Voltage
Range .................................................... 600.0 V
Resolution ............................................... 0.1 V
Accuracy ................................................. 1.5 %
5 digits (45 Hz to 400 Hz)
DC Voltage
Range .................................................... 600.0 V
Resolution ............................................... 0.1 V
Accuracy ................................................. 1 %
5 digits
Resistance
Range ..................................................... 400.0 /4000
Resolution ............................................... 0.1 /1
9