Adjusting Advanced Settings - Sennheiser DW Office Instruction Manual

Dect comfort calls
Hide thumbs Also See for DW Office:
Table of Contents

Advertisement

Putting the headset system into operation
20

Adjusting advanced settings

¸
The DIP switch row
allows you to adjust the headset system to your
individual needs. By default, all DIP switches are set to the upper position.
To change the settings of the DIP switch row ¸:
If necessary, disconnect an existing wireless link between base station
and headset (see page 23).
Use a pointed object (e.g. a pen) to set the DIP switches to the desired
position.
Configuring the handset lifter/hook switch – DIP switch 1 and 2
Switch position
Function
Manual operation
Lifts/hangs up the handset manually or using
the handset lifter.
Electronic hook switch (DHSG standard)
Call control via the DW Office headset system.
Electronic hook switch (MSH standard)
Call control via the DW Office headset system.
Manual operation
Lifts/hangs up the handset manually or using
the handset lifter.
Adjusting the radio range – DIP switch 3
If many DECT systems are operated in a confined space, interference can
occur. In this case, you should change the radio range.
Switch position
Function
Standard radio range
Reduced radio range
Use this setting in order to avoid interference with other
DECT systems.
Range of approx. 10 m indoors
¸