Using the Avaya Remote Supervisor Adapter
Viewing system health summary
The reported voltages for the designated system components are measured in the following ranges:
•
Warning Reset
that the voltage has returned to normal and does not generate any further alerts.
•
Warning
•
Soft Shutdown
second voltage alert is sent and the RSA begins the shutdown of the S8500 Media Server. The
shutdown will be an orderly O/S shutdown. The S8500 Media Server turns itself off when the
shutdown completes.
•
Hard Shutdown
the S8500 Media Server immediately shuts down. The RSA sends out an alarm to the configured
alert recipients.
Fan speed
The RSA monitors the fan running speed of the S8500 Media Server. The speed is express in a percentage
of the maximum fan speed. A fan alert is generated if the fan speed drops in an unacceptable level or the
fan stops.
NOTE:
You must check the associated fan box under the Alerts section for that fan alert to be sent
to the configured alert recipients.
60
: If the voltage returns to a value below the warning reset value, the RSA assumes
: If the voltage reaches or exceeds the value specified for a warning, an alert is generated.
: When the voltage reaches or exceeds the value specified for a soft shutdown a
: When the voltage reaches or exceeds the value specified for a hard shutdown,
Avaya Remote Supervisor Adapter User Guide
June 2004