Duracell POWERPACK 600 Owner's Manual page 49

Hide thumbs Also See for POWERPACK 600:
Table of Contents

Advertisement

Troubleshooting Reference
Table 5-1 Troubleshooting reference
Problem
Measured AC
output voltage
is too low.
Charging
Status light is
OFFwhenAC
charger is
connected
Green
Charging
Status light is
flashing
(indicating
recharging)
and battery
charge (%)
does not tum
on.
38
Possible Cause
Use of an
average-reading AC
voltmeter to read
output voltage.
Battery is almost fully
discharged.
No AC power at the
AC wall outlet.
AC charger is faulty.
Battery charge (%)
reading on digital
display is only
accurate when the
Duracell® Powerpack
has been disconnected
from all appliances
and all charging
sources for 15
minutes.
Solution
The modified sine wave (MSW)
output of the Duracell® Powerpack
requires a true RMS reading meter,
such as the Fluke 87 series, for
accurate measurement.
Press display function button to
verify battery status and recharge the
Duracell® Powerpack as necessary.
"Battery Charge %" reading on the
digital display is only accurate when
the Duracell® Powerpack has been
disconnected from all appliances and
all charging sources for 15 minutes.
Ensure power is available at the AC
wall outlet.
Replace the AC charger.
Unplug the charging sources and any
appliances and let the Duracell®
Powerpack rest for 15 minutes to
obtain an accurate reading.
975-0339-01-01