Choosing a Location
Choosing a Location
WARNING: Fire or explosion
The Duracell® Powerpack contains components that tend to
produce arcs or sparks. To prevent fire or explosion, do not operate
the Duracell® Powerpack in compartments containing batteries or
flammable materials, or in locations that require ignition-protected
equipment.
The Duracell® Powerpack should be operated only in
locations that meet these requirements:
Dry
Cool
Ventilated
Safe
Protected
from battery
gases
12
Do not allow water or other liquids to drop or splash on the
Duracell® Powerpack.
Ambient air temperature should be between 32 and 104°F
(0 and 40°C}-the cooler the better within this range.
Leave at least 2" (5 cm) clearance around the Duracell®
Powerpack for air flow. Ensure that the ventilation openings
are not obstructed.
Do not operate the unit in the same compartment as
batteries or in any compartment capable of storing
flammable liquids like gasoline.
Do not operate the unit where it will be exposed to battery
gases. These gases are very corrosive, and prolonged
exposure will damage the Duracell® Powerpack.