Table 5-1 Troubleshooting reference
Troubleshooting Reference
Problem
Possible Cause
Solution
AC appliance
Battery has discharged Tum the AC outlet
ON/OFF
switch
will not
to 10.5 V.
off and recharge the Duracell®
operate;
Powerpack.
audible alarm
is sounding.
Inverter has
Tum the AC outlet
ON/OFF
switch
overheated due to poor off and allow the Duracell®
ventilation or
Powerpack to cool for 15 minutes or
excessively warm
more. Clear blocked fan opening or
environmental
remove objects covering the unit,
conditions.
then restart the Duracell®
Powerpack.
Move to a cooler environment.
----------------_.--------------
Over-
Inverter has
Tum off the AC outlet
ON/OFF
temperature
overheated due to poor switch, and let the Duracell®
shutdown
ventilation or
Powerpack cool down.
excessively warm
environmental
conditions.
Alarm sounds
Internal battery is
Tum the AC outlet
ON/OFF
switch
nearly discharged.
OFF
and recharge the Duracell®
(11.0 V).
Powerpack.
If you ignore this
warning, the
Duracell® Powerpack
automatically switches
off when the battery
reaches 10.5
V.
Run time is
Internal battery is not
Recharge using the AC charger, until
less than
fully charged.
green Charging Status light is
expected.
steady.
AC appliance power
Check AC appliance power or
consumption is higher
wattage rating (or current draw for
than expected.
12 V DC appliances) and compare
with Table 3-1 on page 15 and Table
3-2 on page 18.