Appendix I: Input Wiring Requirements - Firepower FP-78 Operating Manual

7/8"- 200 volt air plasma cutting power supply
Table of Contents

Advertisement

APPENDIX I: INPUT WIRING REQUIREMENTS

Input
Voltage Freq.
(Volts)
(Hz)
208
50/60
230
50/60
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.
Cable conductor temperature used is 167° F (75° C).
An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should
be used to minimize damage to Plasma Cutting, Welding or power distribution equipment.
NEVER use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.
Flexible cable must have an outside diameter of 0.69 inches (17.5 mm) or greater.
Manual 0-2700
Power Input
Current
1-Ph
1-Ph
(kVA)
(Amps)
14.6
41.7
14.8
38.4
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electrical Code
NOTES
Suggested Sizes (See Notes)
Fuse (Amps)
Wire (AWG)
50
6
40
8
31
Wire (Canada)
6
8