DSC PC1616; PC1832; PC1864 Installation Manual page 5

Powerseries
Hide thumbs Also See for PC1616; PC1832; PC1864:
Table of Contents

Advertisement

PC1616/1832/1864 Wiring Diagram
PC Board
1. Insert Stand off into cabinet
mounting hole in the
desired location. Snap-in-
place.
Cabinet
2. Position circuit board
mounting holes over
standoffs. Press firmly
on board to snap-in-place.
230 V
/50 Hz International
AC
CON1
BAT+BAT-
16.5V
/40VA
AC
FUSE
IMPORTANT:
a)This equipment, Alarm Controller PC1616/1832/1864 shall
be installed and used within an environment that provides the
pollution degree max 2 and overvoltages category II
NON-HAZARDOUS LOCATIONS, indoor only. The equipment is
FIXED and PERMANENTLY connected and is designed to be
installed by service persons only; [service person is defined as a
person having the appropriate technical training and experience
necessary to be aware of hazards to which that person may be
exposed in performing a task and of measures to minimize the risks
to that person or other persons.]
b)The connection to the mains supply must be made as per the local
authorities rules and regulations.
An appropriate disconnect device must be provided as part of the
building installation. Where it is not possible to rely on identification of
the neutral in the AC Mains supply the disconnecting device must
disconnect both poles simultaneously (line and neutral). The device
shall disconnect the supply during servicing.
c)The equipment enclosure must be secured to the building structure
before operation.
e)Internal wiring must be routed in a manner that prevents:
- Excessive strain on wire and on terminal connections;
- Loosening of terminal; connections;
- Damage of conductor insulation
f) Disposal of the used batteries shall be made according to the waste
recovery and recycling regulations applicable to the intended market.
g) Before servicing, DISCONNECT the telephone connection.
WARNING:
High Voltage. Disconnect AC Power
and telephone lines before servicing
Stand Off
Primary:120VAC/60Hz.
Secondary: 16.5VDC 40VA
DSCPTD 1640U
Class II Transformer
NOTE: Do not connect
transformer to receptacle
controlled by a switch
AC AC
To EGND
Terminal
North America Only
Cable Tie (not supplied) recommended
PC1616/1832/1864
High Voltage. Disconnect AC Power
and telephone lines before servicing
CON1
BAT+BAT-
AUX+
BELL+
AC AC
AUX-
NON-POWER LIMITED
WARNING:
Incorrect connections may result in PTC failure or improper operation.
Inspect wiring and ensure connections are correct before applying power.
Incorrect connection of batteries may result in battery rupture or Fire Hazard.
Do NOT allow metal objects to connect the Positive and Negative Terminals.
Ensure that batteries are connected with correct polarity [Red to (+), Black to (-)].
Failure to comply with this may result in battery rupture and/or Fire Hazard.
All circuits are classified for UL Installations as Power Limited/Class II Power Limited
except for battery leads which are not power limited.
Do NOT route any wiring over circuit boards. Maintain at least 1"(25.4mm) separation.
A minimum of 1/4" (6.4mm) separation must be maintained at all points between
power limited wiring and all other non-power limited wiring.
PC1616/1832/1864
AUX+ and Keybus (Red) are Internally Connected
Total current draw from Keypads, PGM Outputs and
Aux circuits must not exceed 700mA
CON1
BAT+BAT-
AUX+
BELL+
PGM1
AC AC
RED BLK YEL GRN
AUX-
BELL-
PGM2
8
9
4
3
1
See corresponding Section NumberText for wiring details.
POWER LIMITED
UA503
WARNING:
PC1864
PC1864
Only
PC1832
Only
RING
PGM1
PGM3
EGND
RED BLK YEL GRN
Z1 COM Z2
Z3 COM Z4
Z5 COM Z6
Z7 COM Z8
TIP
BELL-
PGM2
PGM4
See Section 9
for ground wiring details
12V / 7 AHr
12V / 7 AHr
BLACK
RED
DSC Model BD7-12
or equivalent
Battery
StandbyTime:
24Hrs min.
UA503
REV XX
PC-LINK
10
Internally Connected
PC1864
PC1864
Only
PC1832
Only
PGM3
Z1 COM Z2
Z3 COM Z4 Z5 COM Z6 Z7 COM Z8
PGM4
2
5
Installation
DSC
TB-2
R-1
T-1
DSC
TB-2
RING
R-1
EGND
TIP
T-1
7
6
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerseries pc1616Powerseries pc1832Powerseries pc1864

Table of Contents