G
Shift cable (reverse gate end)
G
Intermediate housing
Using a grease gun, fill the intermediate
housing
with
through the grease nipple 1.
Grease quantity:
Initial 10 hours or 1 month:
33.0–35.0 cm
Every 100 hours or 12 months:
6.0–8.0 cm
4-19
water-resistant
grease
3
(1.11–1.18 oz)
3
(0.20–0.27 oz)
E