Electrical Connections - Tricity Bendix SG210 Operating & Installation Instructions Manual

Gas cooker
Table of Contents

Advertisement

ADVICE FOR SAFETY
Gas connections
Before installation ensure gas type and
pressure and the pre-setting of the
appliance are consistent.
This appliance must be installed only in
a room with good ventilation.
This appliance must not connect to a
flu. It has to be installed and connected
in accordance with the rules in force.
Special attention should be paid to
ventilation requirements.
The adjacent furniture panels have to
be heat resistant or protected by such
material.
The gas type for this appliance is stated
on the rating plate.
Connection to gas supply.
Check that the gas flow and the diameter of
the supply pipe are sufficient to supply all
the appliances of the installation.
Check that all connections are tight.
Install an accessible and visible gas tap
to isolate the appliance.
Installation of flues and ventilation
-
for gas appliances of rated input not
exceeding 60 kW (1
gases) – Part 2 Specification for
installation of ventilation for gas
appliances – BS 5440 Current editions;
Gas burning appliances – Part 3
-
Domestic cooking appliances burning
gas – BS 5386 Current editions;
Specification for installation of low
-
pressure gas pipe wo rk of up to 20mm
(R1) in domestic premises (2
gas) – BS 6891 Current editions;
Pipe threads for tubes and fittings where
pressure-tight joints are made on the
threads (metric dimensions) – BS 21
Current editions;
18
, 2
and 3
family
st
nd
rd
family
nd
Flexible hoses, end fittings and
-
sockets for gas burning appliances – BS
669 Current editions;
Installation of domestic gas cooking
-
appliances (1
, 2
st
nd
BS 6172: 1990 Current editions;
For appliances installed in the Republic
of Ireland please refer to NSAI-Domestic
Gas Installation IS813 Current editions.

Electrical connections

Any electrical work required to
install this cooker should be carried out
by a qualified electrician or competent
person, in accordance with the current
regulations.
THIS COOKER MUST BE EARTHED.
The manufacturer declines any
liability should these safety measures not
be observed.
This cooker is designed to be connected
to a 230-240V AC 50Hz electrical supply.
Before switching on, make sure the
electricity supply voltage is the same as that
indicated on the cooker rating plate. The
rating plate is located on the oven frame.
The cooker is supplied with a 3-core flexible
supply cord incorporating a 13amp plug
fitted. In the event of having to change the
fuse, a 5amp ASTA approved (BS 1362)
fuse must be used. Should the plug need to
be replaced for any reason, the wires in the
mains lead are coloured in accordance with
the following code:
and 3
family gases) –
rd

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sg1wSg210/1w

Table of Contents