STATUS INDICATORS

When the following indicators light up or blink on the operation panel or the following
alphanumeric codes appear in the display, solve the problem immediately referring
to both the table below and the relevant page.
Be sure to use only genuine OLIVETTI parts and supplies.
Drum replacement
required indicator
TD cartridge
replacement
required indicator
Misfeed indicator
SPF misfeed
indicator
Power save indicator is
steadily lit.
The paper tray indicator is
blinking.
"CH" is blinking in the display.
"CH" is steadily lit in the
display.
"P" is blinking in the display.
A letter and a number appear
alternately.
A letter and a number appear
alternately.
60
Indication
Steadily
lit
Blinking
Steadily
lit
Blinking
Blinking
Blinking
Cause and remedy
Replacement of drum cartridge will be needed
soon. Prepare a new cartridge.
Drum cartridge must be replaced. Replace it with
a new one.
Replacement of TD cartridge will be needed
soon. Prepare a new cartridge.
TD cartridge must be replaced. Replace it with a
new one.
A misfeed has occurred. Remove the misfed
paper referring to the description of "MISFEED
REMOVAL".
An original misfeed has occurred in the SPF.
Remove the misfed originals referring to the
description of "D: Misfeed in the SPF".
The unit is in the preheat mode. Press any key to
cancel the preheat mode.
The unit is in the auto power shut-off mode.
Press the start (
) key to cancel the auto power
shut-off mode.
The paper tray is not installed properly. Push the
tray into the unit securely.
The TD cartridge is not installed. Check if the
cartridge is installed.
Side cover is open. Close the side cover securely
by pressing the round projections near the side
cover open button.
The paper tray is empty, or single bypass has
been selected in the printer function.
Load paper.
A misfeed has occurred in the paper tray or
single bypass. Remove the misfed paper.
The scan head locking switch is locked. Unlock
the scan head locking switch and turn the power
switch off/on.
The unit will not function. Turn the power switch
off and then switch it on, and if there is again an
error, remove the power cord from the outlet, and
contact your authorized service representative.
Page
68
56
68
55
61
64
52
52
55
15, 17
61
9