General Nozzle Table - Siemens HSL6EI23 Installation Instructions & Instructions For Use

Table of Contents

Advertisement

Available languages

Available languages

Adjusting the low flame

General nozzle table

Gas type
Natural gas
G20 (E)
Liquefied gas
28-30/
Butane
Propane
G30/G31
Proceed as follows:
• Open the appliance door. Press the control knob
for the oven in and turn it anti-clockwise to the
maximum setting 265.
The gas burner will light. Hold the control knob
pressed in for around 15 seconds and then let go.
• Close the appliance door. Remove the control
knob.
• Through the gas tap opening in the control panel,
loosen the internal setting screw slightly.
• Replace the control knob and heat the oven for
15 minutes.
• Then turn the control knob to the minimum setting
160.
• Remove the control knob again.
• Now, through the gas tap opening in the control
panel, adjust the internal setting screw until a
correct, stable flame is burning.
Loosen the setting screw to increase the gas flow
or tighten it to reduce the gas flow. The setting is
correct when the low flame is around 3 to 4 mm
high.
In the case of a connection to liquefied gas,
tighten the setting screw.
• Replace the control knob again.
• Make sure that the flame does not go out when
the gas flow is changed quickly from maximum to
minimum and vice versa, and when the appliance
door is opened and closed.
Nozzle no.
mbar
Nozzle
Bypass
20
115
Partially
75
37
Burner type
Oven burner
open
0.48
Oven burner
Power
Max. con-
(W)
sumption
2,400
229 l/h
2,400
175 g/h
15