12.4.3Adjusting the gas oven burner minimum setting
1 Light the oven burner and keep it at the maximum for 10/15 minutes.
2 Then turn the knob to the minimum temperature.
3 Extract the gas tap knob and turn the adjustment screw next to the tap rod
(depending on the model) until the correct minimum flame is achieved.
4 Refit the knob and verify that the burner flame is stable (when turning the
knob rapidly from the maximum to the minimum position the flame must not
go out). This procedure must be carried out while the door is closed.
5 (Only for adjustment different from LPG) Open and close the door, if the flame
goes out the minimum must be increased.
If using LPG, the adjustment screw must be tightened to end of stroke. If using city gas or natural gas,
simply unscrew the adjustment screw by a few turns.

12.5 Burner and nozzle characteristics table

Burner
Auxiliary
Semi-rapid
Ultra-rapid
Oven
Burner
Auxiliary
Semi-rapid
Ultra-rapid
Oven
34
Instructions for the installer
Rated heating
capacity (kW)
Nozzle
diameter
(1/100 mm)
1.05
1.8
3.9
2.6
Rated heating
capacity (kW)
Nozzle
diameter
(1/100 mm)
1.05
1.8
3.9
2.6
LPG GAS - G30/G31 28-30/37 mbar
Reduced
capacity (W)
50
400
65
500
100
1600
76
900
NATURAL GAS - G20 20 mbar
Prechamber
(printed on
nozzle)
72
(X)
97
(Z)
135
(K)
120
-
Capacity
Capacity
(g/h G30)
(g/h G31)
76
75
131
129
283
278
189
186
Reduced capacity
(W)
400
500
1600
900