Noise Precautions; Electrical Precautions - Chicago Electric 91523 Operating Instructions Manual

Generator set 6.5 hp - recoil start - 2600w/2800w rated
Table of Contents

Advertisement

1.
Prolonged exposure to noise levels above 85 dBA is hazardous to hearing.
Always wear ANSI approved ear protection when operating or working around
the Generator when it is running.
1.
All connections and conduits from the Generator to the load must only be in-
stalled by trained and licensed electricians, and in compliance with all relevant
local, state, and federal electrical codes and standards, and other regulations
where applicable.
2.
The Generator must be earth-grounded for fixed installations in accordance with
all relevant electrical codes and standards before operation.
3.
If an extension cord (not included) is used, make sure to use only UL approved
cords having the correct gauge and length. (See Figure A.)
REQUIRED MINIMUM EXTENSION CORD GAUGE – 120 VOLT
NAMEPLATE
AMPERES
(At Full Load)
0 - 5
5.1 - 8
8.1 - 12
12.1 - 15
15.1 - 20
4.
Do not attempt to connect or disconnect load connections while standing in
water, or on wet or soggy ground.
5.
Do not touch electrically energized parts of the Generator and interconnecting
cables or conductors with any part of the body, or with any non-insulated
conductive object.
6.
Connect the generator only to a load or electrical system (110/120 volt) that is
compatible with the electrical characteristics and rated capacities of the Genera-
tor.
7.
Before servicing equipment powered by the Generator, disconnect the equipment
from its power input.
SKU 91523

NOISE PRECAUTIONS

ELECTRICAL PRECAUTIONS

EXTENSION CORD LENGTH
0 - 25
25 - 50
Feet
Feet
16
16
16
16
14
14
12
12
10
10
50 -100
Feet
16
14
12
10
10
FIGURE A
PAGE 9
®
100 – 150
150– 200
Feet
Feet
12
12
10
-
-
-
-
-
-
-

Advertisement

Table of Contents
loading

Table of Contents