Turn nozzle upside down and unscrew four (4)
nozzle cover screws. Turn nozzle top side up.
Side
Latch
Lift rear latches up.
Lift agitator assembly out and remove worn belt.
Check and clean end cap areas. See
(page 17) for picture of complete
agitator assembly.
Screws
Rear
Latches
Side
Latch
Base
End Cap
Always follow all safety precautions when performing
maintenance to the nozzle.
Handle
Release
Pedal
Press release pedal and lower the handle.
Grasp the side latches and pull out. Lift cover
upward from back to remove.
End Cap
Cut off any carpet pile, hair or lint entangled around
the agitator and remove any string or debris located
near the end caps.