Dvc-4Io - Monacor DVC–4 IO User Manual

Digital video capture card dvc-series
Table of Contents

Advertisement

1.12 DVC-4IO

To Serial Port on PC
PTZ Signal Cable
RS422/485
Sensor Input
Alarm Output
[ Sensor Input Terminal ]
1. Connection
Connect one signal lineto COM port and connect
Another signal line to the desired sensor number.
2. Operation
- Normal : 1-4 Terminal & COM Port Open
- Sensor Detection : 1-4 Terminal & COM Port
Close
3. At normal close mode, it works reversely.
Notes ;
- N/O : Normal Open
- N/C : Normal Close
- DI Operation Mode (N/O or N/C) can be selected from Setup Mode of Sentry Program
- D/O Delay Time can be adjusted from Setup Mode of Sentry Program
1. Connection
Connect both power lines to DO terminal
2. Operation
- Normal : DO Terminal Open
- Control Output : DO Terminal Close
3 D/O Voltage
.DC 30V, 1A or below
.DC 110V, 0.3A or below
.AC 125V, 500mA or below
Monacor international Co., Ltd.
To DI/DO Terminal
on capture board
[ Alarm Output Terminal ]