Setting of the VTR
Set the VTR as follows;
Example: AG-6730, AG-6740, AG-6760
MENU 3
[VIDEO]
SET TIME
[TIME ADJUSTING]
OPERATION
Connection with Time Lapse VTR
Camera 1 - 4
Intercom 1 - 4
1
2
1
2
1
2
1
2
Coaxial Cable
Notes:
1. To cancel the alarm signal from the monitor, supply the
reset signal of the monitor to the RESET IN connector
of the VTR.
IN
LINE
9:00
MASTER
SPOT MONITOR CONTROL IN
RECOVER
GND
8
7
6
FOCUS
CAMERA
8
7
6
AUDIO IN
BNC Connector
VIDEO IN
RECOVER OUT
ALARM IN
EARTH (GND)
MENU 4
[RESET PULSE]
[CAMERA SW]
MENU 11
[TIME CODE]
A1
E1
A2
E2
B1
F1
B2
F2
C1
G1
C2
G2
D1
H1
D2
H2
Main Unit
Intercom 4
Ground
Intercom 1
Intercom 2
Intercom 3
ALARM
TIMING SELECT
CONTROL
OUT
IN
OUT
5
4
3
2
1
STDBY ALL GND
RESET
MODE
OUT
IN
CAMERA POWER
AUDIO
ON
OFF
VP CAMERA
5
4
3
2
1
REC OUT
PLAY IN
CAMERA INPUT
RCA Connector
ALARM
RECOVER
RESET
IN
GND
GND OUT
OUT
IN
Recover Switch
2. Refer to the Operating Instructions of Time Lapse VTR
for recording details.
3. If you connect RECOVER OUT of the time lapse VTR to
RECOVER IN of this monitor AUTO RESET of this moni-
tor does not work.
-17-
INPUT LEVEL
TIMING
MODE
POSITION
Camera 5 - 8
1
2
Colour Monitor
WV-CM146
Setup Menu Setting;
TIMING SELECT
AUTO RESET
120V
60 Hz
TIMING SELECT IN
AUDIO OUT
VIDEO OUT
Time Lapse VTR
HIGH
1FIELD
TM2
7H, 9H
Intercom 5 - 8
1
2
1
2
1
2
EXT
OFF
CAMERA SW
OUT

Advertisement