Star Trac Pro S Owner's Manual page 44

Treadmill
Hide thumbs Also See for Pro S:
Table of Contents

Advertisement

Lowest
Item
Value
DECELERA-
20
TION TIME
LOCK OUT
-
LOCKOUT ID
10000
RAIL STOP
-
10 REV
220
CNT/REV
31
MINIMUM
4
PWM
1/2 MAXIMUM
50
MAXIMUM
172
PWM
PERSON
1
DETECT 1
PERSON
1
DETECT 2
PERSON
1
DETECT 3
DATE
1.00
NO RAIL
0
STOP
KEY DOWN
0
SPEED CHG
0
ELEV STALL
0
ELEV RANGE
0
ELEV LOST
0
CHECK
0
MOTOR SYS
CHECK
0
SPEED SYS
ELEVATION
175
ZERO
42
Default
Highest
Value
Value
Meaning
20
60
Time, in seconds, to reach 0 mph (0 km/hr) from maximum speed.
OFF
-
ON=Treadmill lock out enabled.
OFF=Treadmill lock out disabled.
12345
65535
Treadmill lockout ID.
OFF
-
ON=Enables handrail stop switch.
OFF=Disables handrail stop switch.
307
740
Tenths of inches of running belt travel for 10 flywheel revolutions, always
measured in tenths of inches. Nominal values are:
1.6" pulley: 275
1.7" pulley: 291
1.8" pulley: 307
2.1" pulley: 358
31
125
Number of counts for each motor shaft revolution. Values are:
RPM sensor at flywheel notches: 31
RPM sensor at motor shaft optical disk: 125
60
110
Pulse duty cycle to obtain the selected MN SPD. Divide MN PWM by 512 to
get % duty cycle.
260
340
Pulse duty cycle to obtain 1/2 maximum speed. Divide 1/2 MX by 512 to get %
duty cycle.
460
511
Pulse duty cycle to obtain the selected MX Spd. Divide MX PWM by 512 to get
% duty cycle.
150
150
NEED DESCRIPTION FOR THIS FUNCTION
150
150
NEED DESCRIPTION FOR THIS FUNCTION
150
150
NEED DESCRIPTION FOR THIS FUNCTION
1.98
12.99
Treadmill manufacture date.
0
65,535
Number of times Hand Rail Stop switch was down or disconnected on power-
up since last reset.
0
65,535
Number of times key other than 5 or 8 was down on power-up since last reset.
0
65,535
Number of times speed changed suddenly more than 2 mph (UNITS=English)
or 2 km/hr (UNITS=Metric) since last reset.
0
65,535
Number of times elevation failed to change (stalled) since last reset.
0
65,535
Number of times elevation was out of range (not between 0% and 15%) at
power-up since last reset.
0
65,535
After pressing S
went beyond 0% to 15%, since last reset.
0
65,535
Number of times the motor system was inoperable.
0
65,535
Number of times the speed system was inoperable.
240
242
Representation of voltage to elevation motor to obtain 0% elevation. Multiply
ELEV ZERO by 0.019608 to get actual voltage.
STAR TRAC PRO S / PRO / ELITE TREADMILL O
and reaching 0% reset, the number of times elevation
TART
'
M
WNER
S
ANUAL

Hide quick links: