ALARM CONTROL

Alarm Mode

When alarm (sensor) is accepted, the matrix switcher's
operation mode changes to the alarm mode. Then, the sys-
tem operates as follows:
• The camera image (alarm image) appears on the moni-
tor 1.
The alarm inputs 1 to 6 are associated with the camera
input connectors 1 to 16.
For example, when the alarm (sensor) connected to the
alarm input 1 becomes active, the camera input con-
nector 1's image appears on the monitor 1.
• "ALARMnn" appears on the monitor.
The display indicates the image is input through the
alarm nn (nn is the alarm number).
When more than one alarm signal input has been
accepted, "ALARMnn
ALARM01
The monitor and alarm number will appear on the LED
display. At the same time, the alarm indicator will blink,
the monitor indicator will light up, and the camera indi-
cator will go out.
* Even when more than one alarm signal has been input,
the matrix switcher system continues to display the
image of the first alarm input.
The display will continue until the first alarm input is
reset.
Notes:
• Alarm input will be automatically reset in 30 seconds.
The auto-recovery time is configurable through SETUP
MENU or SX150 Admin Console.
• The alarm events are configurable through SX150
SETUP MENU or SX150 Admin Console. (Refer to p. 47
ALARM EVENT or p. 58 Alarm Event for details.)

Operating during an Alarm Mode

While an alarm mode is active, the following are available
from the system controller:
• Operating the camera with the alarm input (ACK)
• Resetting the alarm (RESET/ALL RESET)
• Suspending the alarm (ALM SUSPENDED)
86
" appears on the monitor.
*
Operation of an Alarm-related
Camera (ACK)
You can operate the camera with the alarm input as follows:
ACK
RESET
SUSPEND
ALL RESET
GROUP SEQ
TOUR SEQ
T&D
CAM ID
REW/FF
AUX1 OFF
STILL
PREV
NEXT
MON STATUS
ALL
AUX2 OFF
STEP
EL-ZOOM
PAUSE
ALM H
VLD H
DEF OFF
PLAY
PAUSE
SEQUENCE
MON (ESC)
OSD
MON LOCK
SHIFT
MULTI SCREEN SEL
1. Select a monitor which displays "ALARM".
2. Press the ACK button.
"ACK" will appear on the monitor with an alarm input.
The camera with an alarm input will become operable.
3. Operate camera with the system controller.
Pan/Tilt, zoom, focus, and iris are available.
When selecting another monitor, "ACK" will disappear
from the display. The matrix switcher system will return
to the alarm mode.
EVENT
AUX1 ON
AUX2 ON
ACK
SYS S
DEF ON
CAM (SET)
WIPER