Using The Wall-Mounted Door Control; To Open The Door Manually; Care Of Your Garage Door Opener - Raynor ControlHoist ATS2113X-CX Owner's Manual

For residential and light duty commercial use install on sectional doors only commercial door opener
Table of Contents

Advertisement

Using the Wall-Mounted
Door Control
Press the push button to open or close
the door. Press again to reverse the door
during the closing cycle or to stop the
door while it's opening.

To Open the Door Manually

WARNING
To prevent possible SERIOUS INJURY or DEATH from a
falling garage door:
CAUTION
• If possible, use emergency release handle to disengage
trolley ONLY when garage door is CLOSED. Weak or
broken springs or unbalanced door could result in an
open door falling rapidly and/or unexpectedly.
• NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If rope
knot becomes untied, you could fall.
The door should be fully
closed if possible. Pull down
on the emergency release
handle and lift the door
manually. To reconnect the
door to the opener, press the
door control push bar.
The lockout feature prevents
the trolley from reconnecting
automatically. Pull the
emergency release handle
down and back (toward the
opener). The door can then
be raised and lowered
manually as often as
necessary. To disengage the
lockout feature, pull the
handle straight down. The
trolley will reconnect on the
next UP or DOWN operation.
Trolley
Release
Emergency
Arm
Release
Handle
(Pull Down)
MANUAL DISCONNECT
POSITION
Trolley
Release
Arm
Emergency
Release Handle
(Down and Back)
LOCKOUT POSITION
CARE OF YOUR OPENER
LIMIT AND FORCE ADJUSTMENTS:
Weather conditions may
cause some minor changes in
door operation requiring some
re-adjustments, particularly
during the first year of
operation.
Pages 20 and 21 refer to the
limit and force adjustments.
Only a screwdriver is required.
Follow the instructions
carefully.
Repeat the safety reverse test (Adjustment
Step 3, page 22) after any adjustment of limits
or force.
MAINTENANCE SCHEDULE
Once a Month
• Manually operate door. If it is unbalanced or
binding, call a trained door systems technician.
• Check to be sure door opens & closes fully. Adjust
limits and/or force if necessary. (See pages 20
and 21.)
• Repeat the safety reverse test. Make any
necessary adjustments. (See Adjustment Step 3.)
Twice a Year
• Check chain tension. Disconnect trolley first. Adjust
if necessary (See page 7).
Once a Year
• Oil door rollers, bearings and hinges. The opener
does not require additional lubrication. Do not
grease the door tracks.
24
FORCE CONTROLS
9
9
1
1
7
7
3
3
5
5
KG
KG
LIMIT CONTROLS
WARNING
WARNING

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Controlhoist select ats 2113x-cx 1/2 hp

Table of Contents