Parts supplied:
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts
are included.
Parts needed:
Check local codes. Check existing electrical supply and venting.
See "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
Mobile home installations require metal exhaust system
hardware, available for purchase from the dealer from whom
you purchased your dryer. For further information, please
reference the "Assistance or Service" section of the Use and
Care Guide.
Optional
Equipment:
(Not supplied with dryer)
Refer to your Use and Care Guide for information
about
accessories
available for your dryer.
Explosion
Hazard
Keep flammable
materials
and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (460 mm) above the floor
for a garage installation.
Failure to do so can result in death, explosion,
or fire.
You will need:
[]
A location allowing for proper exhaust installation.
See "Venting Requirements."
[]
A separate 15- or 20-amp circuit for gas dryers.
[]
If you are using power supply cord, a grounded electrical
outlet located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements."
[]
A sturdy floor to support dryer and a total weight (dryer
and load) of 200 Ibs. (90.7 kg). The combined weight of
a companion
appliance should also be considered.
[]
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles
may not operate correctly.
Do not operate your dryer at temperatures
below 45°F (7°C).
At lower temperatures,
the dryer might not shut off at the end
of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements.
Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning
appliance can be installed in the
same closet as a dryer.
installation
clearances:
The location must be large enough to allow the dryer door to
open fully.
Most installations require a minimum 51/2"(140 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Dryer Dimensions
43"
(1092 mm)
11092 turn}
133A,,
mm)
•29,?;
.29v2 ,_,
(749 ram} \
(749 mm)
X "X_'_"_
27,,
_\
_ _\
A
B
A. Large opening side-swing
door
B. Wide opening hamper door
installation
Spacing
.H_ 1_"i11BX, ^ __
I_ II_mm_ ' 48in'_
(310crn)
_
24i_*,
...
_ _._ (155cml
1"-'_ _- 27"-_ _
1" -_I"*F
29_/4" H5Y2"*_-
(25rnrn) (686mm) (25mm) _ 5mm}(74,1mm} (140rnrn)
A
B
*Required spacing
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
.._
3 I1.
(76 mm)
-T
4f
3 II,
(76ram}
installation
spacing for recessed
area or closet
The dimensions shown are for the minimum spacing allowed.
[]
Additional
spacing should be considered for ease of
installation and servicing.
[]
Additional
clearances might be required for wall, door, and
floor moldings.
[]
Additional
spacing of 1" (25 mm) on all sides of the dryer is
recommended
to reduce noise transfer.
[]
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
[]
Companion appliance spacing should also be considered.