Install a ULlistedorCSA approved s trainrelief. M ake sure
screwheads arefacing totheleftwhen tightening c onduit
nut.Thestrainreliefmaybeprovided w iththepower
supply cordkit.
• Power S upply Cord:
"
.
- Follow Option A instructions
Direct Wire:
_
Follow Option
B instructions
Make Power Supply Cord Connection
Option A, Power Supply Cord:
Route cord so that it does not touch dishwasher
motor
to lower part of dishwasher
tub. Pull cord through
strain
relief in terminal
bow. Take notice when installing
or
removing
the dishwasher
in order to reduce the chance
of damaging
the power supply cord.
Select UL listed or CSA approved
twist-on
wire connectors
(included with power supply cord kit) rated to connect
your household wiring to 16-gauge dishwasher
wiring.
12
Electrical
Shock Hazard
Electrically
ground dishwasher.
Connect
ground wire to green ground
connector
in terminal
box.
Do not use an extension
cord.
Failure to follow these instructions can result
in
death, fire, or electrical
shock.
Remove the green grounding
screw and place through
the ring terminal
of the green ground
wire. Reattach and
tighten
the green screw.
NOTE: Do not pre-twist
stranded
wire. Twist on wire
connector.
Gently tug on wires to be sure both are
secured.
Connect wires black to black and white to white,
using
UL listed or CSA approved
twist-on
wire connectors
(included
with power supply cord kit).