Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shutoff valve to the closed position.
...................
S
J
..............
< ......................
C
A. Torange
B. Shutoff valve (closed position)
C. Gas supply line
2. Unplug range or disconnect
power.
To Convert Gas Pressure Regulator
Remove the access cap by using a wrench, turning the
access cap counterclockwise.
Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "LP" or "NAT" position. Turn over the spring
retainer so the "NAT" is showing on the bottom. Snap the
spring retainer back into the cap. Reinstall the cap onto the
regulator.
1,
2.
A
¸P
3,
Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure to
the regulator should be as follows for operation and checking
the regulator setting:
Natural Gas:
Minimum pressure 6" (15.2 cm) WCP
Maximum pressure 14" (35.6 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure
shown on the model/serial rating plate.
Line pressure testing above V2 psi gauge (14" WCP)
The range and its individual shutoff valve must be
disconnected
from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2psi (3.5 kPa).
Line pressure testing at V2 psi gauge (14" WCP) or lower
The range must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than _/2psi (3.5 kPa).
To Convert Surface
Burners
1. If the burner grates are installed, remove them.
2. Remove burner cap.
3. Remove the burner base.
_j ...........
A
Large Dual Burner
A. Burner cap
B. Burner base
............ _
.....
Medium
Burner
A. Burner cap
B. Burner base
C. Choke (for use with medium
burner, LP gas only)
Small
Burner
_
A. Burner cap
B. Burner base
L....]
4,
Apply masking tape to the end of a 7 mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Insert nut driver into the gas opening and press down onto
the gas orifice spud and remove by turning the gas orifice
spud counterclockwise
and lifting out. Set gas orifice spud
aside.
E
D
C
A. Access cap
D. NAT position
B. Gasket
E. LP position