Download Print this page

KitchenAid KECD806RSS04 Installation Instructions Manual page 7

30" and 36" electric built-in ceramic downdraft cooktop
Hide thumbs Also See for KECD806RSS04:

Advertisement

I For all cooktop
models
with three-wire
cable from
the cooktop:
Where tocal codes Do Not permit connecting
the frame-
ground conductor
to the neutral (white) junction box
wire. (Used for Canadian
installations):
4=wire cable from power supply
red wires
_Junctiee
box
Ungrounded
white
wire
neutra_
j
Figure 1
twist-on
connector
bare or green
1o Disconnect
wires
U,L,- or CSA- listed
power
supp{yo
3-wire cable
conduit
connector
2o Remove the
junction
fromcooktop
box cover from the junction box inside the cabinet,
3o Connect the flexible, armored cable from the cooktop to the
junction box using a U=L=or CSAqisted conduit connector,
Tighten screws on conduit connector.
4, Connect the two black wires together; then connect the two red
wires together using twist-on connector. (See Figure 1.)
5, Connect the green or bare ground wire from the cooktop cable
to the grounded wire in the junction box or other grounded
connector using twist-on connector,
6o Put a twist-on connector on end of white wire. Do Not connect
bare ground wire to neutra8 (white) wire in junction box,
7. Replace the junction box cover,
Where Jocal codes permit connecting
the frame-ground
conductor
to the neutral (white) junction
box wire. (Not
used for Canadian
installations):
3=wire cable from
power
supply
Grounded
neutra_
Figure
2
redwiL_
__nestor_
--q_r'--,._/junction
twist-on box
white
_
_
Mack
wires
bare or
J
-"
green
wire
3-wire
cable
_J
_
U.L-
or CSA- listed
1. Disconnect
from cooktop
_
conduit
connector
power supply.
2. Remove the junction box cover from the junction box inside
the cabinet,
3. Connect the flexible, armored cable from the cooktop to the
junction box using a U,L- or CSAqisted conduit connector,
Tighten screws on conduit connector,
4. Connect the bare cooktop wire with the white wire; the two
red wires together; and the two black wires together using
twist-on connectors, (See Figure 2,)
5. Replace the junction box cover,
For aH cooktop
models
with four-wire
cable from
the cooktop.
(These
cooktops
are manufactured
with white
[neutron]
power
supply
wire and a cabinet-connected
bare ground
wire factory-crimped
together.):
Where tocaJ codes Do Not permit connecting
the frame-
ground conductor
to the neutraJ (white) junction
box
wire: (Used for Canadian
installations):
4-wire
cable
from power
supply
red wires
J
junction
box
_J
U n g re u n ded
_
white wires
neutra_
Figure 3
_
\twist=on
cormector
green
wires
J
'_Mack
wires
1o Disconnect
4-wire cable
power
supplyo
from cookto
\ U,L,- or CSA- listed
conduit
coneector
2. Remove the junction
box cover from the junction box inside the cabinet,
3. Connect the flexible, armored cable from the cooktop to the
junction box using a U=L- or C=S=A=qisted conduit connector,
Tighten screws on conduit connector,
4. Connect the two black wires together; then connect the two red
wires together using twist-on connectors, (See Figure 3,)
5. Separate the factory-crimped bare and white cooktop cable wires,
6o Connect the two white wires together using twist-on connectors,
7. Connect the bare ground wire from the cooktop cable to the
grounded wire in the junction box or other grounded connector
using twist-on connector, (See Figure 3,)
Do Not connect bare ground wire to neutron (white) wire in
junction
box.
8. Replace the junction box cover=
Where tocaJ codes permit connecting
the frame-ground
conductor
to the neutraJ (white) junction
box wire. (Not
used for Canadian
installations):
3-wire
cable
from
junction
power
supply
box
red
black
Figure 4
white
wire
white
and
grounding oven cable
wires
-- factory
U,L,- or CSA-
crimped
listed
conduit
1. Disconnect
4-wire
cable
from
cooktop
connector
power supply.
2o Remove the junction
box cover from the junction box inside the cabinet,
3o Connect the flexible, armored cable from the cooktop to
the junction box using a U,L- or C,S,A,qisted conduit
connector, Tighten screws on conduit connector,
4, Connect the two black wires together; the two red
wires together; and the factory=crimped bare and
white cooktop cable wires to the white (neutral) wire
in the junction box using twist-on connectors, (See
Figure 4,)
5. Replace the junction box cover,

Advertisement

loading