Remove the warming or storage drawer to gain access to the
lower section of the range. This will be necessary for some of the
following installation steps.
To Remove Warming
Drawer:
1. Open drawer to its fully open position.
2. Locate the black loops on both sides of the drawer.
3=
A
A. Loop
Pull both loops forward at the same time, then pull drawer out
another inch.
4. Holding the drawer by its sides, not its front, gently pull it all
the way out.
To Remove Storage
Drawer:
1. Pull drawer straight out to the first stop.
2. Lift up the back of the drawer and pull out.
IMPORTANT: On models with a warming drawer, the rear range
foot must be viewed from the front and slightly to one side of the
range.
1. Making sure the anti-tip bracket is installed:
Look for the anti-tip bracket securely attached to floor.
Slide range back so rear range foot is under anti-tip
bracket.
2=
If installing the range in a mobile home, you must secure the
range to the floor. Any method of securing the range is
adequate as long as it conforms to the standards in the
"Location
Requirements" section.
If range is not level, pull range forward until rear leveling leg is
removed from the anti-tip bracket.
Use a wrench or pliers to adjust leveling legs up or down until the
range is level. Push range back into position. Check that rear
leveling leg is engaged in the anti-tip bracket.
NOTE: Range must be level for satisfactory
baking performance.
Explosion Hazard
Use a new CSA International
approved
gas supply
line.
Install a shut-off
valve.
Securely
tighten
all gas connections.
If connected
to LP, have a qualified
person make sure
gas pressure
does not exceed 14" (36 cm) water
column.
Examples
of a qualified
person
include:
licensed
heating
personnel,
authorized
gas company personnel,
and
authorized
service
personnel.
Failure to do so can result in death, explosion, or fire.
Typical rigid pipe connection
A combination
of pipe fittings must be used to connect the range
to the existing gas line. Your connections
may be different,
according to the supply line type, size and location.
1. Apply pipe-joint
compound
made for use with LP gas to all
pipe thread connections.
2. Using a pipe wrench to tighten, connect the gas supply to the
range.
.,
>.,, B
/
A
_
F
Place rack in oven. Place level on rack and check levelness of the
range, first side to side; then front to back.
A. Gas pressure regulator
B. 90 ° elbow (must have
Y2" male pipe thread)
C. Nipple
D. Union
E. Black iron pipe
G
F. Manual gas shutoff valve
G. Y2" or _A" gas pipe
H. Nipple
I. Union
J. 90 ° elbow