Direct
Electrical
Connection
to the Circuit
Breaker,
Fuse Box or Junction Box
If the appliance
is connected
directly
to the circuit
breaker,
fuse box or ]unction
box, use flexible,
armored
or nonmetallic
sheathed
copper
cable
(with grounding
wire). Supply a U.L. listed strain-
relief at each end of the cable. At the appliance
end, the cable goes through
the Direct Connection
Hole (see Figure 9) on the Cord Mounting
Plate.
Wire
sizes (copper
wire only) and connections
must conform
to the rating of the appliance.
Where local codes permit connecting the
appllance-grounding
conductor to the neutral
(white)
wire (see Figure 10):
1. Be sure that no power is supplied
on the cable
from residence.
2. Follow instructions
on previous
page for Four
Conductor
Wire
Connection
to Range (Fig. 9).
3. In the circuit
breaker, fuse box or junction box
(Fig. 10):
a) Connect
the green (or bare copper)
wire,
the white appliance
cable wire, and the neutral
(white) wire together.
b) Connect
the 2 black wires together.
c) Connect
the 2 red wires together.
Cable from Residence
Neutral
_ Z-_.._
_
(white) W ir_
:::::_:.'_
Green
L_''_
!; __!
(or Bare
/
_____
Copper) Wire--Z
Cable from
listed)
Appliance
f
_Black
Wires -
Box
_U.L.-iisted
Conduit
Connector (or CSA
NOTE:
Be sure to remove
the
supplied
grounding strap.
Figure 10
3-Wire
(Grounded
Neutral)
Electrical System
(Example:
Junction
Box)
Where local codes DO NOT permit connecting
the appilance-grounding
conductor to the neutral
(white)
wire, or if connecting to 4-wire
electrlca[
system
(see Figure 11):
1. Be sure that no power
is supplied
on the cable
from residence.
2. Follow instructions
on previous page for Four
Conductor
Wire Connection
to Range (Fig. 9).
3. In the circuit
breaker, fuse box or junction box
(Fig. 11):
a)Connect
the white appliance
cable
wire to the
neutral
(white) wire.
b) Connect
the 2 black wires together.
c) Connect
the 2 red wires together.
d) Connect
the green (or bare copper)
grounding
wire to the grounding
wire of the circuit
breaker,
fuse box or junction
box.
Cable from
Green (or Bare
Resider :e
Copper) Wir
___
Red
F
Junction
_' _
BOX
_--_
CaNe from
Appliance
NOTE:
Be sure to remove
the
supplied
grounding
strap.
Figure 11
White
_S
Wire
_Biack
Wire_
White Wire
_U.L.-listed
Conduit
Connector (or CSA
listed)
4-Wire
Electrlca[ System (Example:
Junction
Box)
6. Checking
Operation
Refer to the Use and Care Guide for operation.
_Do
not touch cooktop
glass or
elements.
They may be hot enough to burn you.
Before You Call for Service
Read the Before You Call for Service Checklist
and operating
instructions
in your Use and Care
Guide.
It may save you time and expense.
The
list includes
common
occurrences
that are not the
result of defective
workmanship
or materials
in this
appliance.