iNSTALLATiON AND SERVICEMUST BEPERFORMED BY A QUALifiED iNSTALLER.
iMPORTANT:
SAVE FOR LOCAL ELECTRICAL INSPECTOR'S
USE.
READ AND SAVE THESE iNSTRUCTiONS
FOR FUTURE REFERENCE.
F_
FOR YOUR SAFETY: Do not store or
use
gasoline or other
Nammable
vapors and liquids in the vicinity of this or any other appliance.
.
Clearances
and
Dimensions
a. Provide adequate
clearances
between the range and adjacent
combustible surfaces.
b. Location--Check
location where the range will be installed. Check for proper electrical supply and the stability of floor.
c. Dimensions
that are shown must be used. Given dimensions
provide
minimum
clearance.
Contact
surface
must be solid and level.
United States
SIDE
=
i
i
Maximum d epth _
for cabinets
[;
LS_
25,
O"clearance below cooking top and at rear of range.
30" minimum clearance
between the top of the cooking surface
and the bottom of an unprotected
wood or metal cabinet;
or 24
" minimum when bottom
of wood or metal cabinet
is protected
by not tess than 1/4" flame retardant
millboard
covered with not
less than no. 28 MSG sheet steel, 0.015" stainless steel, 0.024"
aluminum or 0.020" copper. The minimum clearance
is 0" for the
rear of the range. Follow all dimension
requirements
provided
above to prevent property
damage,
potential
fire hazard,
and
incorrect
countertop
and cabinet cuts.
Avoid locating
cabinet storage space above the surface units to
eliminate
the possibility of cabinets catching
on fire, or personal
burns from reaching for the cabinets over the heated
units. If
cabinet storage is to be provided, risk can be reduced by installing
a range hood that projects horlzontally
a minimum
of 5" beyond
the bottom
of the cabinets.
Important
Notes to the Installer
1.
Read all instructions contained
in these installation
instructions
before
installing the appliance.
2.
Remove all packing
material
before connecting
the electrical
supply to the appliance.
3.
Observe all governing
codes and ordinances.
4.
Be sure to leave these instructions with the consumer.
BACK
VIEW
All
dimensions for
electrical
outlet location
ore
....... . maximum.
Cubed
area
shows
Term_ncd
"
where
the electrical
Block
_
outlet
must be installed
Location
_
i
for the range
to be
_qL
_'_-_,_ flush to the wall.
Important
Note to the Consumer
Keep these instructions with your Use and
Care Guide for future reference.
Printed
in Canada
318201736
(1201) Rev. A

Advertisement

Table of Contents
loading

Summary of Contents for Kenmore 79097602301

  • Page 1 iNSTALLATiON AND SERVICEMUST BEPERFORMED BY A QUALifiED iNSTALLER. iMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE. FOR YOUR SAFETY: Do not store or gasoline or other Nammable vapors and liquids in the vicinity of this or any other appliance. United States Clearances Dimensions...
  • Page 2: Tools You Will Need

    2. Tools You Will Need A. Lacate the Bracket Using the Template = Locate the bracket position (right or left side) by placing For leveling legs and Anti-Tip Bracket: the template symmetrically to the center of the final ° Adjustable wrench or channel lock pliers range position.
  • Page 3: Serial Plate Information

    C. Level and position the ranc_ = Slide range to its Range flnat position, Insert the range leveling teg in the anti- Leveling. )_'bl i _I tip bracket. Visually verify if the anti-tip bracket _--- Anti-Tip engaged. Lower the range by adjusting the 4 leveling legs alternatively...
  • Page 4: Electrical Connection

    5. Electrical Connection Requirements The user is responsible for connecting the power supply cord to the connection block located behind This appliance must be properly installed and the back panel access cover. grounded by a qualified technician in accordance with the National Electrical Code ANSI/NFPA This appliance...
  • Page 5: Wire Connection

    Four Conductor Wire Connection to Range This appllance is manufactured Where local codes does NOT permit connection with the frame grounded by connection of a the frame grounding conductor to the neutral wire grounding strap between the neutral power of the copper power supply cord (see Figure 9): supply terminal...
  • Page 6 Direct Electrical Connection to the Circuit Where local codes DO NOT permit connecting the appllance-grounding conductor to the neutral Breaker, Fuse Box or Junction Box (white) wire, or if connecting to 4-wlre electrical If the appliance is connected directly to the circuit system (see Figure 11): breaker,...
  • Page 7 LA INSTALACff.")N Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALiFICADO. iMPORTANTE: GUARDE ESTAS iNSTRUCCIONES PARA USO DEL iNSPECTOR LOCAL DE ELECTRICiDAD. LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA. PARA SU SEGURIDAD: No affnacene nl ufillce gasollna u arras vapores licluidos inflamables en la pro×imldad...
  • Page 8 2. Herramientas que va a necesitar A. Locaffce la fijaci6n usando el papeJ modelo - LocaJice la posici6n de la fijaci6n colocando la plantilla Para paras de nivelaci6n V monfura anfi-vuelco: sim_tricamente a la linea central de la apertura. • Llave ajustable o alicates fijaci6n antivuelco...
  • Page 9 C. Nivele la coclna y coloque la coclna en su lucjar. - Tornillo ___.._. Deslice la estufa a su lucjar. Colocar la pata niveladora dentro de [a fijacione de anti-inciinaci6n. Verifique de la _;.7_c-_Fijaciones visuaimente que ias fijaciones de anti-inciinaci6n estSn estufa de anti-...
  • Page 10 Requlsltos de conexi6n el_ctrlca El utilizador es responsable de la conexi6n del cable Este aparato debe estar instalado en forma apropiada suministro elSctrico al bloque de conexi6n situado detr6s y puesto a tierra por un tScnico caiiflcado, de acuerdo del panel de acceso. con ei National Electric Code (C6digo Nacionai...
  • Page 11 Conexi6n del cable de cuatro conductores a la Este electrodom_stlco rue fabrlcado cocina con el marco aterrlzado a tray,s de una correa 1. Retire los tornillos de la parte baja de la cubierta cone×i6n entre el neutral de la fuente de allmentaci6n del cable trasero (cubierta...
  • Page 12: Antes De Llamar

    Conexi6n el_ctrica directa al corta circuito, a la caja Donde los c6digos locales NO permitan conectar conductor de puesta a tierra del electrodom_stico de fuslbles o la caja de empalmes neutral (blanco), o si est6 conectado con un sistema a 4 Si el aparato est6 conectado directarnente...

Table of Contents